1584, 1583 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 18 hours | 2 hours | 11 hours | 5 hours | 5 minutes | 6 months under conditions described in the User's Guide
12 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 88 hours | 7 hours | 52 hours | 23 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 180 hours | 13 hours | 103 hours | 47 hours | 48 minutes | Indoor Fluorescent Lighting (500 lux) | - | - | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2080, 2017 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 18 hours | 2 hours | 13 hours | 2 hours | 5 minutes | 5 months under conditions described in the User's Guide
10 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 92 hours | 11 hours | 64 hours | 7 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 183 hours | 21 hours | 128 hours | 14 hours | 48 minutes | Indoor Fluorescent Lighting (500 lux) | - | - | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2594, 2184 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 29 hours | 3 hours | 13 hours | 2 hours | 5 minutes | 6 months under conditions described in the User's Guide
12 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 145 hours | 15 hours | 63 hours | 7 hours | 25 minutes | Overcast Sunlight through a Window (5,000 lux) | 290 hours | 29 hours | 126 hours | 15 hours | 50 minutes | Indoor Fluorescent Lighting (500 lux) | - | - | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2704, 2368 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 54 hours | 14 hours | 3 hours | 5 minutes | 6 months under conditions described in the User's Guide
24 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 3 hours | 71 hours | 14 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 5 hours | - | - | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 41 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2422 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 21 hours | 3 hours | 11 hours | 2 hours | 5 minutes | 5 months under conditions described in the User's Guide
10 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 108 hours | 13 hours | 56 hours | 7 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 216 hours | 26 hours | 112 hours | 13 hours | 48 minutes | Indoor Fluorescent Lighting (500 lux) | - | - | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2472, 2471 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 50 minutes | 12 hours | 2 hours | 5 minutes | 5 months under conditions described in the User's Guide
23 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 2 hours | 60 hours | 10 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 4 hours | - | - | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 32 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2514, 2513, 2512 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 52 minutes | 15 hours | 2 hours | 5 minutes | 6 months under conditions described in the User's Guide
24 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 2 hours | 67 hours | 13 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 4 hours | - | - | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 37 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2536, 2535, 2534, 2532, 2531 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 65 minutes | 18 hours | 4 hours | 5 minutes | 9 months under conditions described in the User's Guide
24 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 4 hours | 98 hours | 19 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 7 hours | - | - | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 60 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2568 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 33 hours | 3 hours | 16 hours | 2 hours | 5 minutes | 6 months under conditions described in the User's Guide
11 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 166 hours | 16 hours | 80 hours | 12 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | - | 33 hours | 162 hours | 25 hours | 48 minutes | Indoor Fluorescent Lighting (500 lux) | - | - | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2591, 2590 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 24 hours | 15 hours | 17 hours | 5 minutes | 11 months under conditions described in the User's Guide
21 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 122 hours | 76 hours | 85 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | - | 155 hours | 172 hours | 48 minutes | Indoor Fluorescent Lighting (500 lux) | - | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2597 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 75 minutes | 24 hours | 5 hours | 5 minutes | 10 months under conditions described in the User's Guide
24 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 4 hours | 120 hours | 23 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 8 hours | - | - | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 130 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2609, 2608, 2607 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 1 hour | 14 hours | 3 hours | 5 minutes | 6 months under conditions described in the User's Guide
21 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 3 hours | 70 hours | 14 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 5 hours | 143 hours | 28 hours | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 57 hours | - - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2616, 2615, 2611 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 90 minutes | 25 hours | 7 hours | 5 minutes | 12 months under conditions described in the User's Guide
26 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 6 hours | 126 hours | 35 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 11 hours | - | - | 48 minutes | Indoor Fluorescent Lighting (500 lux) | - | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2629 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 1 hour | 15 hours | 4 hours | 5 minutes | 7 months under conditions described in the User's Guide
24 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 4 hours | 73 hours | 20 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 6 hours | 148 hours | 41 hours | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 66 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2639, 2638, 2637 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 1 hour | 14 hours | 3 hours | 5 minutes | 6 months under conditions described in the User's Guide
21 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 3 hours | 70 hours | 14 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 5 hours | 143 hours | 28 hours | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 57 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2654 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 1 hour | 14 hours | 4 hours | 5 minutes | 11 months under conditions described in the User's Guide
26 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 4 hours | 67 hours | 19 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 6 hours | - | - | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 60 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2689, 2688, 2687 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 1 hour | 14 hours | 3 hours | 5 minutes | 6 months under conditions described in the User's Guide
21 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 3 hours | 70 hours | 14 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 5 hours | 143 hours | 28 hours | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 57 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2832, 2696 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 2 hours | 24 hours | 7 hours | 5 minutes | 9 months under conditions described in the User's Guide
24 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 6 hours | 118 hours | 33 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 8 hours | - | - | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 89 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2730, 2727 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 1 hour | 13 hours | 4 hours | 5 minutes | 5 months under conditions described in the User's Guide
24 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 3 hours | 66 hours | 18 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 5 hours | - | - | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 45 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2752 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 1 hour | 18 hours | 5 hours | 6 minutes | 7 months under conditions described in the User's Guide
24 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 4 hours | 92 hours | 25 hours | 30 minutes | Overcast Sunlight through a Window (5,000 lux) | 6 hours | - | - | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 67 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2763 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 1 hour | 14 hours | 4 hours | 5 minutes | 5 months under conditions described in the User's Guide
24 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 3 hours | 71 hours | 20 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 5 hours | - | - | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 49 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2766 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 1 hour | 15 hours | 4 hours | 5 minutes | 6 months under conditions described in the User's Guide
16 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 4 hours | 76 hours | 21 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 6 hours | 124 hours | 34 hours | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 56 hours | - - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2803, 2802 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 2 hours | 24 hours | 7 hours | 5 minutes | 11 months under conditions described in the User's Guide
26 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 7 hours | 119 hours | 33 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 10 hours | 242 hours | 67 hours | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 117 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2804 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 21 hours | 3 hours | 18 hours | 3 hours | 5 minutes | 6 months under conditions described in the User's Guide
12 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 108 hours | 14 hours | 94 hours | 13 hours | 25 minutes | Overcast Sunlight through a Window (5,000 lux) | - | 28 hours | 188 hours | 25 hours | 50 minutes | Indoor Fluorescent Lighting (500 lux) | - | - | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2810 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 24 hours | 15 hours | 17 hours | 5 minutes | 11 months under conditions described in the User's Guide
22 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 122 hours | 76 hours | 85 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | - | 154 hours | 171 hours | 48 minutes | Indoor Fluorescent Lighting (500 lux) | - | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
2819, 2818 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 1 hour | 14 hours | 3 hours | 5 minutes | 6 months under conditions described in the User's Guide
21 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 3 hours | 70 hours | 14 hours | 24 minutes | Overcast Sunlight through a Window (5,000 lux) | 5 hours | 143 hours | 28 hours | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 57 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
| | | |
|
 |
3330 | Lighting Level | Battery Level | Required Exposure per Day | Approximate Operation on Full Charge without Further Charging | | | Bright Outdoor Sunlight (50,000 lux) | 1 hour | 18 hours | 5 hours | 6 minutes | 7 months under conditions described in the User's Guide
24 months in the Sleep State | Bright Sunlight through a Window (10,000 lux) | 4 hours | 92 hours | 25 hours | 30 minutes | Overcast Sunlight through a Window (5,000 lux) | 6 hours | - | - | 48 minutes | Indoor Fluorescent Lighting (500 lux) | 67 hours | - | - | 8 hours |
|
|  |  | Important! | | The above values are guidelines only. Actual required exposure time depends on a variety of environmental factors. |
|
|